Overview 

Rainscreen SA Matrix Penny 032521 web

Self-adhered air, water, and vapor barrier flashing

Storage and Handling

Store material rolls on end in original packaging. Protect rolls from direct sunlight and inclement weather until rady for use.

Preparation

All surfaces must be dry, sound, clean, “as new” condition, and free of oil, grease, dirt, excess mortar, or other contaminants detrimental to the adhesion of the water resistive air barrier membrane and flashings.
Fill voids and gaps in substrate greater than 7/8 inch (22.2 mm) in width to provide an even surface.

Installation

Use roller to activate pressure-sensitive adhesive. Best practice is to cover flashing as soon as practical.

Limitations

VaproFlashing SA should be covered within 12 months of installation. Minimum recommended application temperature of 20˚F (-6˚C) and rising. VaproFlashing SA is installed on most substrates without primer. Specific jobsite conditions may require additional surface preparation with primer, contact VaproShield Technical.

Compatible Substrates

  • Exterior Gypsum Sheathing
  • Rigid Insulation
  • OSB
  • Concrete
  • Brick
  • Plywood
  • Metal (Steel, Aluminum)
  • Fiberglass Window and Door Frames
  • Wood Blocking

 

Rough Opening Detail

Rough Opening Detail Image 01

Rough Opening Detail Image 03

Install VaproFlashing SA directly to the sheathing and fold inside the rough opening

Rough Opening Detail Image 04

Tool a bead of VaproBond or other VaproShield approved sealant at all corner seams.

Rough Opening Detail Image 05

Release film from the bottom of the flashing to be left attached for shingling over membrane.