pdf PDF Download (1.52 MB)

PHYSICAL PROPERTIES

PROPERTY

RESULT

Color

White

Thickness

10.2 mil (0.26 mm)

Membrane Weight
(without release film)

0.95 oz/yd² (289 g/m²)

60" Roll Weight
(with release film)

48 lbs (22 kg)

30" Roll Weight
(with release film)

25 lbs (11 kg)

Roll Dimensions

60" x 100' (1.5 m x 30.5 m)
30" x 100' (.76 m x 30.5 m)

Roll Coverage

60" 500 ft² (46.5 m²) gross
30" 250 ft² (23.2 m²) gross

Primer

No Primer Required
Primer may be required when applying to structural concrete

VOCs

None

Field Exposure Before Permanent Cladding

6 months

Minimum Application Temperature

20°F (-6°C) and rising

Service Temperature

minus 40°F (-40°C) - 270°F (132.2°C)

AAMA 711-13

Compliant

 

TESTING DATA

PROPERTY

STANDARD

RESULT

Strength

Elongation

ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension

MD - 409%
XMD - 276%

Tensile Strength

ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension

MD - 16.96 MPa (2460 psi) XMD - 11.87 MPa (1721 psi)

Dry Tensile Strength

ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting

MD - 3.85 N/mm (22 lbf/in)
XMD - 3.85 N/mm (22 lbf/in)

Elongation at Break

ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting

MD - 541%
XMD - 617%

Dry Breaking Force (Grab method) MD ≥40 XMD ≥35

ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)

MD – 338 N (76 lbsf)
CD – 356 N (80 lbsf)

Elongation at Break

ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)

MD - 120%
XMD - 157%

Minimum Puncture Resistance

ASTM E154 Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover

Deflection 5.84 cm (2.3")
Max Load 249 N (56 lbf)

Cold Mandrel Bend Test

AC38 Section 3.3.4

PASS

Weathering Tests

AC38 Section 4.1.2 UV Exposure AC38 Section 4.1.3 Accelerated Aging

PASS

Wear Resistance Wheelbarrow Testing PASS
Self Adhering Flashing AAMA 711-13 Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products Compliant

Water Vapor Transmittance

Water Vapor Transmission Desiccant Method Procedure A 23°C (73.4°F) 0-50 %RH

ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials

0.0173 Perm (grain/h•ft²•inchHg) @23°C 100%RH
0.992 ng/Pa•s•m²

Water Vapor Transmission Using Modulated Infrared Sensor

ASTM F1249 Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor

0.0193 Perm (grain/h•ft2•inchHg) 1.10 ng/Pa•s•m2

Water Ponding ICC-ES AC48 Acceptance Criteria for Self-Adhered Roof Underlayments for use as IBarriers PASS

Air Resistance Testing

Air Permeance

ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials

0.00912 L/s•m² @ 75 Pa (0.0018 cfm/ft² @ 1.57 psf)

Air Permeance

CAN/ULC-S741-08 (2020) Standard for Air Barrier Materials

PASS

Air Leakage Rate

CAN/ULC-S742-11 Standard for Air Barrier Assemblies

Class A1

 

Water Resistance Testing

Nail Sealability

ASTM D1970 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection Section 7.9 referring to ASTM D7349 protocol 4 with modifications

PASS

Water Resistance (Control after Weathering)

AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists

PASS

Fire Testing

Flame Spread Smoke Developed

ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Flame Spread 5 (Class A)
Smoke Developed 15

UL

UL790 Test Method of Fire Tests for Roof Coverings, CAN/ULC-S107

PASS

Surface Burning Characteristics CAN/ULC-S102 Protective Underlayment, Permeable to Allow Drying, Provides an Air Barrier Flame Spread Rating: 5
Smoke Developed Value: 15

 

ROOF TESTING DATA

PROPERTY

STANDARD

RESULT

Uplift Strength

FM LPDS 1-52 Field Verification of Roof Wind Uplift Resistance

Steel Deck 11.12 kN/m² (232.5 psf)

90-Degree Peel Strength ASTM D3330 Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape. Method F Steel Deck
879 N/m (5.02 lb/in)
Gypsum Board
751 N/m (4.29 lb/in)
Coated Fiberglass Faced Board
380 N/m (2.27 lb/in)

REGISTER FOR OUR WEBINARS TODAY