pdf Printer Friendly (PDF) (1.92 MB)

PHYSICAL PROPERTIES
PROPERTY RESULT

Color

Black/Yellow

Thickness

0.45 mm (18 mil)

Membrane Weight

355.64 g/m2 (1.17 oz/ft2)

Roll Weight (with release film)

48.6 lbs (22 kg)

Roll Dimensions

59” x 102’ (1.5m x 31m)

Roll Coverage

500 ft2 (46.65 m2)

Skid

25 Rolls

Primer

No Primer Required

VOCs

None

Field Exposure Before

Permanent Cladding

12 months

Minimum Application

Temperature

20° F (-6°C)

Service Temperature

Minus 40°F (-40°C) - 250°F (121°C)

Warranty

20 year material warranty

 

TESTING DATA
PROPERTY STANDARD RESULT

Strength

Dry Tensile Strength ≥ 20 lbs/in

ASTM D828 Standard Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus

MD – 6.6 N/mm (37.7 ibs/in)

Dry Breaking Force (Grab method) MD ≥40 XMD ≥35

ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)

MD – 529 N (119 lbsf)

CD – 427 N (96 lbsf)

Cold Mandrel Bend Test

AC38 Section 3.3.4

Warp (Machine) Direction - No cracking Filling (Cross) Direction - No cracking

Weathering Tests

AC38 Section 4.1.2 UV Exposure AC38 Section 4.1.3 Accelerated Aging

UV - No visual change UV & Accelerated - visibly lighter, no visible deterioration

Water Vapor Transmittance

Water Vapor Transmission

Dynamic Relative Humidity Measurement (23°C 50 %RH)

ASTM E398 Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement

26.02 Perm (grain/h•ft2•inchHg) 1489 ng/Pa•s•m2

Adhesion Testing

90˚ Peel Adhesion

AAMA 711

PASS

Air Resistance Testing

Air Permeance

ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials

0.0001 L/s•m2 @ 75 Pa (0.0000 cfm/ft2 @ 1.57 psf)

Air Barrier

ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies

<0.01 L/s•m2 @ 75 Pa (<0.002 cfm/ft2 @ 1.57 psf)

Air Barrier

ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

<0.01 L/s•m2 @ 75 Pa (<0.01 cfm/ft2 @ 1.57 psf)

Water Resistance Testing

Nail Sealability

ASTM D1970/ section 7.9 Standard Specification for Self-Adhering Polymer

Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection

Pass - Review Fastener Penetrations Technical Bulletin

Water Resistance (Boat Test)

ASTM D779 Standard Test Method for Water Resistance of Paper, Paperboard, and Other Sheet Materials by the Dry Indicator Method (Withdrawn 2011)

Control - No leakage Weathered - No Leakage

Water Resistance (Control after Weathering)

AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists

Control - No leakage Weathered - No Leakage

Fire Testing

Flame Spread Smoke Developed

ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Flame Spread 0 Smoke Developed 20

Cone Calorimeter Testing Data ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

Time to ignition: 7 sec
Flame Duration: 78 sec
Ave. Effective Heat of Combustion: 6.1 MJ/kg
Ave. HRR at 60 sec: 58 kW/m²
Ave. HRR at 180 sec: 62 kW/m²
Peak HRR: 132 kW/ m²
Time of Peak: 52 sec.
Total HRR/A: 6.5 MJ/m²