SlopeShield SA Self-Adhered Testing

Printer Friendly (PDF)

Approvals and Testing

PROPERTY STANDARD/TEST RESULT
Breaking Strength/Elongation

ASTM D5034
AC 48, Section 4.1

MD – 88 lbf (391 N)
CD – 83 lbf (369 N)
PASS

Water Vapor Transmission (WVT) and Permeance

ASTM E398-13

51.74 U.S. Perms**
359.50 g/m² 24 hrs (WVT)**

Air Permeance ASTM E2178

0.00002 cfm/ft2
0.0001 L/s/m2
PASS

Water Ponding

AC 48, Section 4.4
24" head of water for 48 hrs

PASS
Accelerated Aging

AC48, Section 4.7
AC207, Section 4.6

PASS
UV Exposure

AC48, Section 4.8
AC207, Section 4.7

PASS
Liquid Water Transmission

ASTM D4869
AC207, Section 4.3

PASS
Rupture Resistance

ASTM D3462
AC207, Section 4.4

PASS
Pliability

ASTM E48
AC 207, Section 4.2

PASS


Independent Testing

PROPERTYSTANDARD/TESTRESULT
Nominal Thickness Calibrated Micrometer 0.022 inch (0.56 mm)
Basis Weight Electronic Weight Scale

7.37 oz/yd² (0.819 oz/ft²)
250 g/m²

** Review SlopeShield SA Self-Adhered Sustainability Statement

Application

ROOF SLOPEAPPLICATION
1:12 For slip sheet applications only
2:12

Minimum 12" (305 mm) Horizontal/Vertical Lap Seams
VaproLiqui-Flash™ or VaproShims™ SA Self-Adhered required under metal clips and similar penetrations

3:12

Minimum 12" (305 mm) Horizontal/Vertical Lap Seams
VaproLiqui-Flash™ or VaproShims™ SA Self-Adhered required under metal clips and similar penetrations

4:12 and greater

Minimum 6" (152 mm) Horizontal/Vertical Lap Seams
Neither VaproLiqui-Flash™ or VaproShims™ SA Self-Adhered are required for clips

 

Printer Friendly English (PDF, 736 Kb)